Plate Formation

MCR Series (charge only) and MCDR Series (charge/discharge) cabinets contain multiple circuit configuration typically 6 to 16 circuits configured on basis of power rating & volume of batteries required as per production convenience. The cabinet is designed to Interface with Acid Circulation System

The SCR series offers the rugged power electronics module, time tested & very reliable unit.
The Rectifier cabinet works on program schedule set in the Battery Manager software. However the rectifier start is controlled from the ACS system, depending on readiness for current flow into the battery.

Standard cabinet consists of similar Power rating circuits, 3Amps upto 600Amps. The circuits can be started, stopped, operated individually or as a group from the Battery Manager software.

  • Automotive plate formation with Tack/Tackless process
  • Tubular battery plate formation
  • Plate formation for Standby industrial batteries
  • Formation of plates for Plante cells
  • Rugged design manufactured under excellent quality practices ensures trouble free operation
  • Automatic polarity reversal for Tackles operation
  • Current Range: 100amp to 600amp, Voltage Range: 120Vdc up to 300Vdc
  • Automated Operation from HOST PC with Battery Manager software
  • Ease of Service & flexible to operate
  • Charge Only / Charge-Discharge operations provided from universal module
  • Automatic Restart after a power fail/Outage with a memory backup
  • Flexible program schedules meeting any formation requirement
  • Cooling arrangements provided for robust working under difficult site conditions
Standard DC Voltage Range 120V – 300V
Standard DC Current Range ± 100Amp to ± 600Amp
Measuring Accuracy Udc < ± 1.5% FSR
System Efficiency, % ** @90% at rated output
Galvanic Isolation per circuit Yes
Mains Connection 3phase, 415V/400V, 50hz/60hz, N + E
Ambient Temperature 45°C
Mode of Operation Constant current & Constant Potential
PC Software Battery Manager

COOLING & ENVIRONMENT CONDITIONS

Cooling Air Cooled, air flow from bottom to top
Protection Level IP20
Humidity 10% – 90% RH, non-condensing and non-corroding

CABINET

Degree of protection IP20
Color RAL-7032 Siemens Grey

STANDARD MODELS

Model Designation Nominal DC current Nominal DC Voltage No. of Thanks
TCR Series,
Forward/Reverse
100 ~ 600 100 ~ 300 40/50/60/100
CDC Series
Charge-Discharge series
100 ~ 600 100 ~ 300 40/50/60/100